REQUEST SAMPLES
color AIR-board® panels with polycarbonate-facing sheets are characterized by translucent optics and interesting 3D light scattering effects. The fire-resistant and UV stable panels can be combined freely in color, core design, form (2D), and thickness together with many additional features.
Interior design, wall / ceiling, partitions, doors, shop and exhibition construction, stage construction, artistic applications, furniture, lighting design.
Format | Length [mm/inches] | Width [mm/inches] | Thickness [mm/inches] |
---|---|---|---|
Standard | 3020/118.8 | 1000/39.3 | 19/0.75 |
Special Dimensions*/** | max 3500/137 | max 1500/59 | max 30/1.18 |
Cut to size | 2/-2 to 0.08/-0.08 | 1/-2 to 0.04/-0.08 | 0/-1 to 0/-0.04 |
*on request – minimum orders apply for special sizes
Coefficient of thermal expansion acc. to DIN 537522-A [1/K] |
---|
6.5 x 105 |
Service temperature [oC/F] |
-30 to +80 / -22 to 176 |
G Value (total energy transmission value) based on solar angle |
0.72 (0o), 0.67 (30o), 0.61 (45o), 0.52 (60o) |
Thickness [mm/inches] |
Weight per unit area [kg/m2/lbs/sqft] |
Thermal insulation U-value [W/M2K] |
Sound insulation RW [DB] |
Modulus in Elasticity [N/MM 2] |
---|---|---|---|---|
12/0.47 | 5.4/1.1 | 3.2 | 21 | NA |
16/0.63 | 5.6/1.15 | 2.7 | 21 | 1300 |
19/0.74 | 5.9/1.20 | 2.4 | 21 | 930 |
30/1.18 | 6.6/1.35 | 1.8 | 23 | 750 |
*per 1m panel width
Fire Classification | ASTM D-2843 Smoke Density [%] |
ASTM D-635 Burning Rate [inches] |
ASTM D-1929 Self Ignition Temp. [oF] |
ASTM E648-17/NFPA253 WATTS/CM2 |
* ASTM E-84 Flame Spread Index |
---|---|---|---|---|---|
C2/CC2 | 8.2% | 1.14″ | 853 | >1.10 | 50 |
* ASTM-E84 – 19a “Standard Method of Test for Surface Burning Characteristics of Building Materials”.
The foregoing test procedure is comparable to UL 723, ANSI/NFPA No. 255, and UBC No. 8-1.